Campus Solna
Wallenberglab, Hörsal CMB
Quick facts
- Year Built: 1996
- Architect: Mikael Dunge arkitektkontor
- Address: Berzeliusväg 19b, Liljestrands väg 5a, Berzelius väg 21
- Facility ID: A0095048
- Property Designation: Haga 4:35
Campus Solna
Address: Campus Solna, Berzelius väg 21, 171 65 Solna. Everything. von Eulers väg 5a, 171 65 Solna.
Subway, commuter train and bus connections are within walking distance. Campus Solna can be reached by car and parking is offered in the area and managed by Q-park AB. Bicycle parking and air stations are available in the area.
You can find more information at www.sl.se
On campus you will find a wide range of services, study places, restaurants and cafés. The campus area offers plenty of outdoor environments, meeting places and sports activities.
For a complete list of services on campus visit www.ki.se
Staff and visitors are directed to paid parking spaces within Campus Solna. Parking space intended for vans with a permit for the disabled is at the main entrance von Eulers väg 5a. Please see the campus map for Campus Solna .
Bicycle parking is available in several places around the buildings.
SAFE – WARN – ALARM – EXTINGUISH
Evacuation alarm in case of fire
There are smoke detectors in corridors, public and technical areas that automatically trigger an evacuation alarm in the event of fire smoke. Alarms are indicated by bells or sirens supplemented by flashing lights in corridors. In public spaces such as the entrance area and auditoriums, a spoken message is heard. In the event of a fire, call 112 as the evacuation alarm is not directly forwarded to the Rescue Service.
You can manually trigger the alarm yourself using push buttons in escape routes. Limit the source of the fire by closing windows and doors.
Fire cells
The building is divided into a number of fire cells to prevent fire and smoke from spreading. Each fire cell is delimited by fire-rated walls and doors. In principle, all floors, stairwells, lifts, operating areas and waste rooms have their own fire cells. Doors in fire cell boundaries can be set in the open position for transport with magnetic suspension and closed manually with a push button marked "fire door closer". When an evacuation alarm is triggered, the doors close automatically within the alarmed area.
Doors in fire cell boundaries must absolutely not be blocked or set up with wedges or the like!
Escape routes/assembly point
At least two escape routes can be reached from each workplace. The escape routes, which are marked with green, luminous escape signs, must never be blocked. The green signs are always lit and have a battery backup to illuminate even in the event of a power cut.
If the fire alarm is triggered, all staff must leave the building, close all doors behind them and gather at the assembly point which is Nobel Forum, Nobels väg 1. The staff report there to the evacuation receiver. No one may depart from the assembly point until this is done.
Car parking
A parking space intended for vehicles with a permit for people with reduced mobility can be found next to the entrance. Please see the campus map for Campus Solna .
Entrance and lift
The entrances are equipped with a ramp but no automatic door opener. All business floors can be reached via lift.
RWC
Toilets adapted for the disabled are available on each business floor and are equipped with a local security alarm. Alarms are indicated locally by sound and a red flashing light outside each room. It is important that you who see and hear this alarm contact the person who needs help. Alarms are reset in each room by pressing the reset button.
Some source sorting takes place locally on each floor. In the building's waste room, waste is sorted into different fractions. Akademiska Hus is responsible for removal of household waste and the tenant for other waste fractions.
When receiving goods, the tenant is responsible for removing pallets and packaging.
Other waste
Waste such as radioactive, chemical and biological waste is handled according to special regulations.
Generally
In public areas such as corridors and stairwells, the lighting is time-controlled. In addition to the set time, the lighting is switched on manually via push buttons and switched off automatically.
Laboratories
In the lab, lighting is turned on and off manually via a push button inside the door. If it is desired to turn off individual ceiling luminaires, pull switches on the luminaires can be used. Please note that the ceiling fixture must be manually switched on again when lighting is desired again.
Generally
In order to obtain good air quality in the premises, the ventilation is adapted to the number of people and the equipment planned for the rooms.
Office and conference room
In offices and conference rooms, the normal temperature can usually be influenced via a regulator on the wall. Normally “auto mode” should be set. The fan speed is then adapted to the person and heat load, in addition to a continuous basic flow.
Laboratories
The ventilation in the lab is needs-based. This means that the air circulation, in addition to a continuous basic flow, changes when the door is opened during work at ventilated workplaces.
Protective ventilation
Work with dangerous and/or volatile chemicals must be done at ventilated workplaces. Protectively ventilated units are available i.a. in the form of hoods, hoods and ventilated cabinets. Chemicals must be stored in ventilated cabinets.
In order for the ventilation to produce the desired effect, it is essential to follow the instructions at each workplace. To provide a full protective effect, windows in the vicinity of the workplace must be kept closed when drafts disturb the air flow.