MIT-huset

Quick facts
- Year Built: 1992
- Architect: A. Olsson & Sjödin
- Address: Campustorget 5
- Facility ID: J0008019
- Property Designation: Stadsliden 6:6
Umeå
Error report:
Is something wrong in your house? Submit an error report to Akademiska Hus via the app or on our website. Enter any room number when reporting a fault. The room number is indicated on the door post.
In case of urgent errors outside normal working hours (Monday-Friday, 07.30-16.00) you can call the emergency number 070-510 10 02.
Locking:
The house is equipped with a time-controlled central locking system. In addition to regular working hours, an access card with a code is required for access.
When exiting through locked doors, press the button with the key symbol located next to the door. Also make sure the door locks.
There are separate containers for waste sorting in the building's garbage room/environment room. Akademiska Hus is responsible for emptying the garbage room. The tenant is responsible for removing bulky waste, pallets and larger packaging.
The following sorting:
- Paper
- Corrugated cardboard/Cardboard
- Colored and uncolored glass
- Metal
- Plastic packaging, LDPE
- Food waste
-Mixed waste
Recycled paper is sorted, handled and paid for directly by each tenant within the tenant's premises.
Waste such as chemical and biological waste is sorted, handled and paid for directly by each tenant within the premises.
General/Corridors
The lighting in the corridors is switched on by time channel. In addition to the time channel, it is switched on by presence.
Office
The offices are equipped with LED fixtures. They turn on when there is presence and can be dimmed with a pull cord.
Classrooms
The classrooms are equipped with LED fixtures. They are turned on and off via a switch or turned off in the evening via a switch-off pulse.
Fire
Fire protection work is carried out on an ongoing basis. Generally, the landlord is responsible for fire protection outside the premises and the tenant for fire protection inside the premises. This is regulated in the lease agreement.
It is important not to store, place or leave anything in the stairwell or in public areas that could pose a fire risk, make it difficult to access and clean, or be disruptive to the well-being of the occupants.
Evacuation takes place via the respective stairwell. Each tenant is responsible for ensuring that there is an updated evacuation plan.
The building is equipped with an evacuation alarm in the event of a fire. In the event of smoke, smoke detectors trigger an evacuation alarm throughout the building and a signal to evacuate is given via a doorbell. If a fire is detected, call 112, as the evacuation alarm is not directly forwarded to the Rescue Services. Try to limit the fire source by closing windows and doors.
You can manually trigger the alarm yourself using push buttons in escape routes.
Detailed information about the building regarding fire cells, evacuation/assembly points, security alarms RWC, ventilation & gas alarms is formulated and described in the rental agreement. Contact your contact person at Akademiska Hus or customer service if you have any questions.
Personal and elevator alarms
It is possible to send an emergency signal from elevators. When the push button is held down for more than 15 seconds, a signal sounds outside the door and an alarm is sent to Akademiska Hus. After regular working hours, the alarm is sent to on-call staff or security guards.
Alarms from elevators are reset by operating personnel.
HEAT
The house has a so-called water-based heating system for heating elements on the exterior walls.
The desired temperature is set using a thermostat placed on the radiator or, if available, via a room sensor placed on the wall.
Cold
Some rooms with high heat loads are cooled with chilled beams placed in the ceiling. The temperature is controlled via room sensors. In rooms where chilled beams are installed, the desired temperature can be set on the room controller placed on the wall.
Parts of the house are cooled via cooled supply air which is regulated via a set temperature.
Car parking
Parking spaces intended for vehicles with a handicap permit can be found close to the main entrance. Please see Campus map.
Entrances and lifts
The entrances are accessible and all floors can be reached via lift.
RWC
Toilets adapted for the disabled are available on each floor. At the RWC there are security alarms with red push buttons labeled "emergency signal". Alarms are reset inside each room by pressing the reset button.
Generally
Ventilation normally runs during the day and is started/stopped via a time channel. Outside regular office hours, ventilation can be started using timer push buttons.
In the auditorium, teaching rooms, computer labs and seminar rooms, ventilation is controlled by presence, temperature and carbon dioxide. The light courtyards are equipped with ventilation hatches and awnings that are controlled by the prevailing weather and time of day.
In lecture halls and group rooms, there are signs posted indicating the number of people the premises are designed for.