Umeå
Lärarutbildningshuset

Quick facts
- Year Built: 1996
- Architect: Bertil Håkansson, FFNS
- Address: Universitetstorget 30
- Facility ID: J0008026
- Property Designation: Stadsliden 6:6
Umeå
Solar cells:
There are solar cells installed on the roof.
Error report:
Is there something wrong with your house? Report a fault to Akademiska Hus on our website. Please include your room number when reporting a fault. The room number is listed on the doorpost.
In case of emergency problems outside of regular working hours (Monday-Friday, 7:30 a.m.-4:00 p.m.), you can call the emergency number 070-510 10 02.
Locking:
The teacher training building is equipped with an electronic central locking system. Outside of regular working hours, an access card and code must be used. When exiting through locked doors, press the button with the key symbol.
There are separate containers for waste sorting in the building's garbage room/environment room. Akademiska Hus is responsible for emptying the garbage room. The tenant is responsible for removing bulky waste, pallets and larger packaging.
The following sorting:
- Paper
- Corrugated cardboard/Cardboard
- Colored and uncolored glass
- Metal
- Plastic packaging, LDPE
- Food waste
-Mixed waste
Recycled paper is sorted, handled and paid for directly by each tenant within the tenant's premises.
Waste such as chemical and biological waste is sorted, handled and paid for directly by each tenant within the premises.
General/Corridors
The lighting is switched on via push button in the morning and automatically switched off in the evening. At night, the lighting can be switched on by push buttons and switched off automatically after a while.
Cafe (light yard)
The lighting is switched on by push button and switches off automatically in the evening. If it is bright outside, however, the lighting cannot be switched on (the pushbutton is lit during the time that the lighting can be switched on).
Office
All office lighting is switched on and off manually via push buttons.
Force
Within the Teacher Training, a 5-wire system has been installed, which reduces electromagnetic fields that can occur with electrical installations.
Interventions must not be done!
If changes are needed in the electrical system, contact Akademiska Hus.
Fire
Fire protection work is carried out on an ongoing basis. Generally, the landlord is responsible for fire protection outside the premises and the tenant for fire protection inside the premises. This is regulated in the lease agreement.
It is important not to store, place or leave anything in the stairwell or in public areas that could pose a fire risk, make it difficult to access and clean, or be disruptive to the well-being of the occupants.
Evacuation takes place via the respective stairwell. Each tenant is responsible for ensuring that there is an updated evacuation plan.
The building is equipped with an evacuation alarm in the event of a fire. In the event of smoke, smoke detectors trigger an evacuation alarm throughout the building and a signal to evacuate is given via a doorbell. If a fire is detected, call 112, as the evacuation alarm is not directly forwarded to the Rescue Services. Try to limit the fire source by closing windows and doors.
You can manually trigger the alarm yourself using push buttons in escape routes.
Detailed information about the building regarding fire cells, evacuation/assembly points, security alarms RWC, ventilation & gas alarms is formulated and described in the rental agreement. Contact your contact person at Akademiska Hus or customer service if you have any questions.
Personal and elevator alarms
It is possible to send an emergency signal from elevators. When the push button is held down for more than 15 seconds, a signal sounds outside the door and an alarm is sent to Akademiska Hus. After regular working hours, the alarm is sent to on-call staff or security guards.
Alarms from elevators are reset by operating personnel.
The house has a so-called water-borne system for heating elements on the outer walls and cooling beams on the roofs. The desired room temperature can be individually set on a sensor placed on the wall.
With the help of the setpoint switch, the room temperature can be adjusted according to the user's wishes. By moving the switch upwards to the plus sign, the room temperature is raised, by moving it downwards to the minus sign, the room temperature is lowered. Preset room temperature is around 20°C. If the room temperature exceeds the set value by more than 2°C, the cooling starts.
Entrances and lifts
The entrances are accessible and all floors can be reached via lift.
Car parking
Parking spaces intended for vehicles with a handicap permit can be found close to the main entrance. Please see Campus map .
RWC
Toilets adapted for the disabled are available on each floor. At the RWC there are security alarms with red push buttons labeled "emergency signal". Alarms are reset inside each room by pressing the reset button.
Generally
Ventilation normally runs during the day and is started/stopped by a time channel.
In fume cupboards and classrooms, ventilation can be forced using timer push buttons. Outside of regular operating hours, the ventilation unit is also started.
The light courtyards are equipped with ventilation hatches that are controlled by the prevailing weather and time of day.
Remember not to open windows outside office hours as this may trigger an alarm!
In classrooms and group rooms there are signs posted indicating the number of people the premises are designed for.