Umeå
Universitetsbiblioteket

Quick facts
- Year Built: 1968
- Architect: Lennart Lundström
- Address: Biblioteksgränd 12
- Facility ID: J0008030
- Property Designation: Stadsliden 6:6
Umeå
Error report:
Is something wrong in your house? Submit an error report to Akademiska Hus via the app or on our website. Enter any room number when reporting a fault. The room number is indicated on the door post.
In case of urgent errors outside normal working hours (Monday-Friday, 07.30-16.00) you can call the emergency number 070-510 10 02.
Locking:
The building is equipped with an electronic central locking system. During times when the building is locked, an access card with the associated code is required for access.
When exiting through locked doors, press the button with the key symbol next to the door.
There are separate containers for waste sorting in the building's garbage room/environment room. Akademiska Hus is responsible for emptying the garbage room. The tenant is responsible for removing bulky waste, pallets and larger packaging.
The following sorting:
- Paper
- Corrugated cardboard/Cardboard
- Colored and uncolored glass
- Metal
- Plastic packaging, LDPE
- Food waste
-Mixed waste
Recycled paper is sorted, handled and paid for directly by each tenant within the tenant's premises.
Waste such as chemical and biological waste is sorted, handled and paid for directly by each tenant within the premises.
Generally
In corridors, certain fluorescent fixtures constitute so-called LED lighting. The fixtures are turned on and off together with regular lighting and in some places via presence detectors.
Lighting in toilets is controlled locally with motion detectors.
Offices and workplaces
Installed LED fixtures in parts of the house that are controlled via push button and presence.
Replacement to LED with presence control is ongoing.
In other areas, there are fluorescent fixtures that are equipped with high-frequency ballasts (HF ballasts) for flicker-free light.
Fire
Fire protection work is carried out on an ongoing basis. Generally, the landlord is responsible for fire protection outside the premises and the tenant for fire protection inside the premises. This is regulated in the lease agreement.
It is important not to store, place or leave anything in the stairwell or in public areas that could pose a fire risk, make it difficult to access and clean, or be disruptive to the well-being of the occupants.
Evacuation takes place via the respective stairwell. Each tenant is responsible for ensuring that there is an updated evacuation plan.
The building is equipped with an evacuation alarm in the event of a fire. In the event of smoke, smoke detectors trigger an evacuation alarm throughout the building and a signal to evacuate is given via a doorbell. If a fire is detected, call 112, as the evacuation alarm is not directly forwarded to the Rescue Services. Try to limit the fire source by closing windows and doors.
You can manually trigger the alarm yourself using push buttons in escape routes.
Detailed information about the building regarding fire cells, evacuation/assembly points, security alarms RWC, ventilation & gas alarms is formulated and described in the rental agreement. Contact your contact person at Akademiska Hus or customer service if you have any questions.
Personal and elevator alarms
It is possible to send an emergency signal from elevators. When the push button is held down for more than 15 seconds, a signal sounds outside the door and an alarm is sent to Akademiska Hus. After regular working hours, the alarm is sent to on-call staff or security guards.
Alarms from elevators are reset by operating personnel.
Car parking
Parking spaces intended for vehicles with a handicap permit can be found close to the main entrance. Please see Campus map.
Entrances and lifts
The entrances are accessible and all floors can be reached via lift.
RWC
Toilets adapted for the disabled are available on each floor. At the RWC there are security alarms with red push buttons labeled "emergency signal". Alarms are reset inside each room by pressing the reset button.
Generally
General ventilation is controlled via a time channel and follows the library's opening hours.
Office
The office area is controlled via a time channel and follows the office's opening hours, normally set to 6:00 p.m. on weekdays. Outside working hours, it is possible to start the ventilation via a push button.